Concrete Grade M35: Strength, Mix Ratio, and Uses

M35 concrete reaches a characteristic cube strength of 35 newtons per square millimeter at 28 days. Here is what goes into it and where it belongs.

Characteristic strength: 35 N/mm² cube at 28 days
Grade designationM35
Characteristic cube strength35 N/mm²
Approximate cylinder strength28 N/mm²
Mixdesign mix only
Typical cement contentcommonly 360 to 420 kg per cubic meter, by design
Typical usesprestressed concrete, bridge decks, structural precast

Notes for design and site

M35 appears where early strength and tight quality control pay for themselves: precast yards demolding on a daily cycle and prestressing beds that need strength before transfer. Expect superplasticizers, controlled curing, and cube results tracked on control charts rather than hoped for.